3000ºC Ultra-High temperature vacuum (air filed) environmental test device/ furnace
01 Overview
The heating device adopts 3 electric heating to achieve 600ºC~3000ºC experimental temperature. It has good soaking zone, temperature fluctuation, and temperature gradient.
The intelligent thermostat controller adopts a mult-channel temperature controller with high-precision and rapid response, advanced control algorithm including fuzzy logic PID regulation and parameter self-tuning function, which can control various temperature indicators, control the conduction range of DC power supply on the switch. Imported high precision noncontact photocolormeter with average heating speed of 10ºC/s~100ºC/s.
The grip has the following type:
1. High temperature grip and deformation measuring device for 2800ºC round specimen;
2. High temperature grip and deformation measuring device for tensile test of 2800ºC plate specimen;
3. High temperature grip and deformation measuring device for 2800ºC round sample compression test;
4. 2800ºC retangular sample compression test high temperature clamp and deformation measuring device;
5. High temperature grip and deformation device for 3-point bending test of 2800ºC rectangular specimen.
Deformation measurement stretching and compression are measured by high-temperature extensometer, range ±3mm, resolution 0.1μm, precision 0.5%; the high temperature-resistant differential transformer is used for the deflection measurement of the high-point bending test, range 0~10mm, resolution 0.1μm, precision 0.5%, or can use high temperature resistant non-contact measurement deformation.
02 Features
· Can complete the stretching, compression, bending and other tests in an ultra-high temperature environment
· The deflection measurement of the three-point bending test is measured by the high temperature resistant differential transformer;
· Photocolorometer directly controls temperature, high temperature with good uniformity and small fluctuation
· The high temperature vacuum (aerify) environmental device adopts stainless steel double-layer water cooling structure to ensure the stability and safety of the equipment during the test.
· The deformation measurement adopts two high temperature vacuum extenometer to measure the average value;
· Vacuum and charging protective gas environment test to prevent oxidation of the test sample;
· Heating voltage is less than the safe voltage, heating speed depends, high temperature stable speed is fast;
· Test environments with different oxygen concentrations are achieved
03 Application sample
3000 ºC Energized heating high-temp vacuum (aerify) environment tensile mechanical performance test device |
04 Factory & Packing & Delivery
05 Certificate