1600ºC Radiation Heating High-temp Atmospheric Environment Test Device/ Furnace
01 Overview
The heating device is heated by silicon molybdenum rod with achieve experimental temperature of 800 ºC - 1600ºC.
The intelligent temperature control meter is adjusted by the 0.1 level Al regulate, and the average heating speed is 3ºC/min~ 15ºC/min.
Deformation measurement stretching and compression by high temperature extenometer, with range ± 5mm, resolution 1 µm, accuracy of 0.5%.
02 Features
· Stable work for a long time, and have a long time dynamic calibration function;
· Can complete the tensile creep, lasting, relaxation, pull-pull creep fatigue and strain-pressure creep fatigue test;
· Deformation measurement adopts high temperature water cooling side plug extensometer to measure deformation;
· Small stove can be selected to achieve cold end grip;
· Thermocouple directly controls the temperature, with slow heating speed, short insulation time and small fluctuation.
1600ºC radiation heating heated high temperature atmospheric environment pull and pressure creep fatigue mechanical performance test device
03 Factory & Packing & Delivery
04 Certificate